{"product_id":"sonoff-thermostat-core-zigbee-smart-thermostat-tp-wgzba","title":"Sonoff-C Thermostat Core Zigbee Smart Thermostat | TP-WGZBA","description":"\u003ch2\u003eSonoff Thermostat Core Zigbee Smart Thermostat | TP-WGZBA\u003c\/h2\u003e\n\u003cp\u003eThe SONOFF Thermostat Core (TP-WGZBA) is a flush-mounted Zigbee 3.0 wall thermostat for water (hydronic) heating systems and boilers. It has a powered relay output for heating actuators and a separate potential-free dry contact for a boiler, a physical dial for setting the temperature, and weekly heating plans managed through a SONOFF Zigbee gateway.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e White\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0868\/5643\/3971\/files\/TP-WGZBA_EN_1600_01.jpg\" alt=\"SONOFF Thermostat Core TP-WGZBA feature overview\" style=\"width:100%;height:auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Outputs for Hydronic Heating \u0026amp; Boilers:\u003c\/strong\u003e The active relay output drives heating actuators up to 3A (resistive load), and the passive dry-contact output (COM \/ NO) switches a boiler without putting voltage on its terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0868\/5643\/3971\/files\/TP-WGZBA_EN_1600_03.jpg\" alt=\"SONOFF TP-WGZBA dual output for underfloor heating actuators and boilers\" style=\"width:100%;height:auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree Weekly Heating Plans:\u003c\/strong\u003e Store three independent temperature plans, each covering a full week with up to 12 time periods per day, and switch between weekday, weekend or holiday routines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDial Control \u0026amp; Presence Wake-Up:\u003c\/strong\u003e Set the temperature with the physical dial. Built-in radar presence sensing wakes the display when you approach (detection distance about 0.3 m, 0.6 m or 1 m), and the screen brightness is adjustable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWindow-Open Detection \u0026amp; Remote Sensor:\u003c\/strong\u003e When a window is opened the thermostat stops calling for heat. It can also link to a SONOFF door\/window sensor, and use a SONOFF Zigbee temperature sensor on the same gateway as the room-temperature source for more accurate readings. Child lock and anti-freeze mode are included.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0868\/5643\/3971\/files\/TP-WGZBA_EN_1600_06.jpg\" alt=\"SONOFF TP-WGZBA wiring for hydronic actuator and boiler dry contact\" style=\"width:100%;height:auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWho it's for \/ Works with:\u003c\/strong\u003e Homes with hydronic (water) underfloor heating or a boiler that want app, schedule and automation control. It needs a SONOFF Zigbee gateway with the eWeLink app; Apple Home is supported through a SONOFF Matter bridge, and it works with Zigbee2MQTT (2.14.0 or newer for full functionality).\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0868\/5643\/3971\/files\/TP-WGZBA_EN_1600_07.jpg\" alt=\"SONOFF TP-WGZBA compatible mounting box sizes\" style=\"width:100%;height:auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGood to know:\u003c\/strong\u003e Designed for water heating systems — electric underfloor heating mats generally exceed 3A and must not be connected directly. Native ZHA support is still in progress. An external NTC floor sensor (10KΩ, B3950) is supported but not included. Italian 503 back boxes need an adapter.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;\" border=\"1\" cellpadding=\"6\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eTP-WGZBA\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless\u003c\/td\u003e\n\u003ctd\u003eZigbee 3.0 (IEEE 802.15.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable system\u003c\/td\u003e\n\u003ctd\u003eWater (hydronic) heating system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eFlush wall mount; in-wall depth 31.5 mm; screw hole distance 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input\u003c\/td\u003e\n\u003ctd\u003e100-240V~ 50\/60Hz, max 3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator output\u003c\/td\u003e\n\u003ctd\u003eActive relay output, max 3A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoiler output\u003c\/td\u003e\n\u003ctd\u003ePassive dry contact (COM, NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature setting range\u003c\/td\u003e\n\u003ctd\u003e5°C – 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadar detection distance\u003c\/td\u003e\n\u003ctd\u003eLow ≈0.3 m \/ Medium ≈0.6 m \/ High ≈1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal floor sensor\u003c\/td\u003e\n\u003ctd\u003e10KΩ NTC, B value 3950K (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86 × 86 × 45.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e155 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C – 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e≤90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended wire\u003c\/td\u003e\n\u003ctd\u003e24AWG – 12AWG (0.2 – 3.5 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic operation cycles\u003c\/td\u003e\n\u003ctd\u003e10,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e📄 User manual:\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0868\/5643\/3971\/files\/SONOFF-TP-WGZBA-User-Manual-EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload the official SONOFF TP-WGZBA user manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n","brand":"Sonoff","offers":[{"title":"Default Title","offer_id":67731362382131,"sku":"TP-WGZBA","price":50.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0868\/5643\/3971\/files\/TP-WGZBA.jpg?v=1792262148","url":"https:\/\/nasertech.com\/products\/sonoff-thermostat-core-zigbee-smart-thermostat-tp-wgzba","provider":"متجر نصر","version":"1.0","type":"link"}